摘要:为获取电缆隧道火灾参数,研究隧道内空气温度及火灾烟雾体积分数随时间、空间的分布情况,应用美国国家标准和技术研究院(NIST)开发的以火灾中流体运动为主要模拟对象的计算流体动力学软件FDS对工业电缆隧道火灾进行全尺寸模拟,通过对模拟实验数据进行处理和分析,给出了电缆隧道发生火灾时烟气体积分数和氧气体积分数以及纵向温度的变化规律,为现实灭火救援以及火灾中逃亡提供了理论依据.
DOI:10.16186/j.cnki.1673-9787.2008.02.017
分类号:TM75
FDS in electric cable tunnel fire application
Abstract:In order to gain the cable tunnel conflagration parameter, distribution condition of tunnel inner air dampness and conflagration smoke fog thickness following time, space is studied.The fluid moves (Fire Dynamics Simulator) calculation flow mechanics software FDS, which mainly to simulate a marriage partner in the conflagration is built by using USA national standard and development of the technology research institute (NIST) .The conflagration carries out the full-size simulation on industry cable tunnel.Through the data handling simulating and experiment analysis, change law smoke thickness and oxygen thickness and longitudinal temperature of cigarette is given when the cable tunnel conflagration happened, It provids the theory basis of a fire rescue escape in the conflagration.