| Time: 2026-11-23 | Counts: |
Zhao L, He S C, Zhang Q,et al.Removal of fluoride from domestic wastewater treatment plant effluent using a constructed wetland with thermally modified coal gangue as filter media[J].Journal of Henan Polytechnic University(Natural Science) ,2027,46(1):88-97.
doi:10.16186/j.cnki.1673-9787.2024030073
Received:2024/03/26
Revised:2024/05/27
Published:2026/11/23
Removal of fluoride from domestic wastewater treatment plant effluent using a constructed wetland with thermally modified coal gangue as filter media
Zhao Li1,2, He Shichang1, Zhang Qing1,2, Zhu Kaipeng3, Xing Mingfei1,2, Zhang Yiyang1,2, Li Yusong4
1.School of Resources and Environment, Henan Polytechnic University, Jiaozuo 454003, Henan, China;2.Henan Engineering Research Center of Intelligent Monitoring and Treatment of Water Environment, Jiaozuo 454003, Henan, China;3.Key Laboratory of Coal Mine Water Hazard Prevention and Control, Technology in Shaanxi Province, Xi’an 710077, Shaanxi, China;4.No.2 Institute of Geo-Environmental Survey of Henan, Zhengzhou 450000, Henan, China
Abstract: Objectives The feasibility of using coal gangue as filter media in constructed wetlands for advanced treatment of municipal wastewater treatment plant effluent was evaluated to reduce treatment costs and promote the resource utilization of coal gangue. Methods A simulation experiment was conducted using coal gangue thermally modified by calcination at 600 °C for 2 h as the filter medium. Adsorption kinetics and isotherm models were used to characterize fluoride removal. An unmodified coal gangue group was included for comparison, and soaking tests were conducted to determine heavy metal concentrations in the leachate. Results Fluoride adsorption by both unmodified and thermally modified coal gangue followed a pseudo-second-order kinetic model, and the adsorption isotherms of both materials were described by the Langmuir model. Column tests showed that fluoride removal from the effluent was relatively stable and was greater with thermally modified coal gangue. The mean fluoride concentrations in the effluent from columns 1 and 2 were 0.503 and 0.233 mg/L, respectively; the corresponding mean removal rates were 24.53% and 65.06%. The thermally modified coal gangue was mildly acidic, which lowered the effluent pH; however, the effluent remained weakly alkaline. Heavy metal leaching from the coal gangue before and after calcination was well below the limits in the national standard, indicating a low environmental risk. Conclusions These findings provide a theoretical basis for evaluating the feasibility of using coal gangue for advanced treatment of municipal wastewater treatment plant effluent and support the reduction of wetland treatment costs and the resource utilization of coal gangue.
Key words:thermally modified coal gangue;constructed wetland;municipal wastewater treatment plant effluent;fluoride;removal